Solar Energy
Home > Product > Application Oriented > Solar Energy
  • MD0630T41A AC DC GFCI Protection Leakage Sensor Fault Current Monitoring RCM Device for Solar PV Arrays
  • MD0630T41A AC DC GFCI Protection Leakage Sensor Fault Current Monitoring RCM Device for Solar PV Arrays

MD0630T41A AC DC GFCI Protection Leakage Sensor Fault Current Monitoring RCM Device for Solar PV Arrays

Share :
Product parameters

Product Details

MD0630T41A is a high-sensitivity AC DC leakage current sensor for solar inverter residual current detection, which can also be called residual current monitoring (RCM), residual current detection (RCD), differential current sensor, earth leakage detector, zero phase current transformer, and fault current sensor. Dedicated to detection Type AC, A, F, B, and B+ leakage current measurement. 


It has the characteristics of accurate measurement, small size, and integration. The RCD sensor can be set separately for AC and DC leakage and has a digital output function. It can detect sinusoidal AC, pulsating DC, composite of multi-frequency as well as smooth DC residual currents. and are suitable for many industries include electric vehicle charging stations, photovoltaic systems (solar panels), industrial devices, heat pumps, DC screens, fire distribution cabinets, and marine boats. It is the technology that brings us closest to total protection for all known residual fault currents.


MD0630T41A AC DC Ground Fault Protection RCM Residual Current Monitoring Leakage Sensor for Solar PV Array


Product Features

AC/DC residual current detection, range AC3-100mA/DC 2-15mA  

Space-saving/Compact design, Vertical/Horizontal Mount

Default Threshold for 6 mA DC and 30 mA AC, Digital Outputs

Measurement resolution of DC 0.2 mA/AC 0.3mA  

AC DC Leakage Data Readable, Alarm Value Programmable, 3 Way Alarm Outputs

UART Comm, with Modbus Protocol, CE-EMC/TUV Certified

Complies with Applications Using These Standards: IEC 62955, IEC 62752, IEC 61851-1


Product Parameters

  • Wide voltage input: 12V±20%

  • Measuring current range: DC current 2-15mA; AC current 3-100mA (default threshold: DC 6mA, AC 30mA)

  • Accuracy class: at 25℃, DC±0,2mA, AC±0.3mA

  • Working environment temperature: -25℃~+80℃

  • Installation: Pin&Cable Type

  • Plastic casing: SIP encapsulation


Typical Application

MD series residual current sensor (RCD/RCM) is an ideal protection device for the detection and protection of different leakage currents/residual currents/fault currents. The RCD could quickly output an alarm signal when people get an electric shock or leakage current exceeds stipulated value, protecting personal and electrical equipment safety.

MD0630T41A AC DC Ground Fault Protection RCM Residual Current Monitoring Leakage Sensor for Solar PV Array